Instrument Compatibility Chart
Assay
Instrument
Read-Out
Specifications
ADP Quest™
ADP Quest™ HS
ADP Hunter™ Plus
ADP Hunter™ HS
ADP Quest™ HS
ADP Hunter™ Plus
ADP Hunter™ HS
EnVision- Perkin Elmer
Resorufin/Amplex Red FP 535/40 filter (Cat. #2100-5570)
Emission 595/60 filter
(Cat. #2100-5530)
Victor- Perkin Elmer
Excitation Filter for VICTOR™,
530 nm,
15 mm Diameter, 8 nm Bandwidth
(Cat. #1420-529)
Emission Filter for VICTOR™,
590 nm, 25.4 mm Diameter, 10 nm Bandwidth (Cat. #1420-5860)
ViewLux- Perkin Elmer
Excitation 525 nm Filter, 20 nm Bandwidth (Cat. #11440175) Emission: 598 nm Filter, 25 nm Bandwidth (Cat. #11440174)
Molecular Devices Excitation 535 nm, Emission 590 nm
SpectraMax Gemini XPS/EM - Molecular Devices Excitation: 530 Emission: 590
FlexStation 3 - Molecular Devices: SpectraMax M2/M2e/M3/M4/M5/M5e
Excitation: 530 Emission: 590
PolarStar Optima- BMG
Excitation 544 nm; Emission
590 nm
Tecan Ultra & Spectra Excitation 530 nm Emission 590 nm
Resorufin/Amplex Red FP 535/40 filter (Cat. #2100-5570)
Emission 595/60 filter
(Cat. #2100-5530)
Victor- Perkin Elmer
Excitation Filter for VICTOR™,
530 nm,
15 mm Diameter, 8 nm Bandwidth
(Cat. #1420-529)
Emission Filter for VICTOR™,
590 nm, 25.4 mm Diameter, 10 nm Bandwidth (Cat. #1420-5860)
ViewLux- Perkin Elmer
Excitation 525 nm Filter, 20 nm Bandwidth (Cat. #11440175) Emission: 598 nm Filter, 25 nm Bandwidth (Cat. #11440174)
Molecular Devices Excitation 535 nm, Emission 590 nm
SpectraMax Gemini XPS/EM - Molecular Devices Excitation: 530 Emission: 590
FlexStation 3 - Molecular Devices: SpectraMax M2/M2e/M3/M4/M5/M5e
Excitation: 530 Emission: 590
PolarStar Optima- BMG
Excitation 544 nm; Emission
590 nm
Tecan Ultra & Spectra Excitation 530 nm Emission 590 nm
Fluorescence
Read Fluorescence Intensity signal:
Resorufin Excitation- 530 nm
Resorufin Emission- 590 nm
Read-time - 1 sec/well
Resorufin Excitation- 530 nm
Resorufin Emission- 590 nm
Read-time - 1 sec/well
ADP Quest™
ADP Quest™ HS
ADP Hunter™ Plus
ADP Hunter™ HS
ADP Quest™ HS
ADP Hunter™ Plus
ADP Hunter™ HS
Molecular Devices:
SpectraMax® Gemini
SpectraMax® Gemini
Fluorescence
Read Fluorescence Intensity signal:
Resorufin Excitation - 530 nm
Resorufin Emission - 590 nm
Mode: Kinetic
Resorufin Excitation - 530 nm
Resorufin Emission - 590 nm
Mode: Kinetic
Calcium No
WashPLUS
WashPLUS
All fluorometers with on-board fluidics
Molecular Devices- FLIPR, FlexStation 3
HAMAMATSU - FDSS
Molecular Devices- FLIPR, FlexStation 3
HAMAMATSU - FDSS
Fluorescence
Excitation 494 nm
Emission 516 nm
Emission 516 nm
Coelenterazine
CYBIO - LUMAX
HAMAMATSU - FDSS
Perkin Elmer: LUMILUX
HAMAMATSU - FDSS
Perkin Elmer: LUMILUX
Flash
Luminescence
Luminescence
CCD imager 1 minute to 5.5 minutes for a 384 well plate
HitHunter® cAMP
HitHunter® cGMP
All PathHunter®
assays
HitHunter® Kinase Binding Assays
HitHunter® cGMP
All PathHunter®
assays
HitHunter® Kinase Binding Assays
COMPATIBLE WITH ANY LUMINOMETER
BMG: PheraStar, Cytostar, LumiStar
Perkin Elmer: TopCount, Victor 2 or V, Fusion, LumiCount, Envision, Micro-beta (Trilux), Viewlux, Northstar
GE: LEAD seeker, Farcyte
Molecular Devices: FLIPR, SpectraMax M3/M4/M5/M5e, FlexStation 3, SpectraMax L
Tecan: Ultra, Evolution
Turner BioSystems: Modulus Microplate
Caliper LabChip 3000 & EZ Reader
Berthold Technologies- Mithras LB940
Hamamatzu FDS6000, FDSS/RayCatcher
Thermo Scientific: Luminoskan Ascent
Berthold: CentroLIApc
Biotek: Synergy 2
BMG: PheraStar, Cytostar, LumiStar
Perkin Elmer: TopCount, Victor 2 or V, Fusion, LumiCount, Envision, Micro-beta (Trilux), Viewlux, Northstar
GE: LEAD seeker, Farcyte
Molecular Devices: FLIPR, SpectraMax M3/M4/M5/M5e, FlexStation 3, SpectraMax L
Tecan: Ultra, Evolution
Turner BioSystems: Modulus Microplate
Caliper LabChip 3000 & EZ Reader
Berthold Technologies- Mithras LB940
Hamamatzu FDS6000, FDSS/RayCatcher
Thermo Scientific: Luminoskan Ascent
Berthold: CentroLIApc
Biotek: Synergy 2
Luminescence
FOR PMT-based luminometer:
GLOW settings
Read the plate for 1 second/well
CCD-based luminometer,
10 - 30 second image
GLOW settings
Read the plate for 1 second/well
CCD-based luminometer,
10 - 30 second image
HitHunter® IP3
BMG: POLARstar Galaxy
Molecular Devices:
Perkin Elmer: Fusion™
Universal & VICTOR2 V
Tecan: ULTRA Evolution
Biotek - Synergy 2
Beckman Coulter MTX 880
plate reader.
Molecular Devices:
Perkin Elmer: Fusion™
Universal & VICTOR2 V
Tecan: ULTRA Evolution
Biotek - Synergy 2
Beckman Coulter MTX 880
plate reader.
Fluorescence Polarization
Excitation Filter Fluorescein- 485 nm
Emission Filter Fluorescein- 530 nm
Dichroic Fluorescein- 505 nm
Emission Filter Fluorescein- 530 nm
Dichroic Fluorescein- 505 nm
HitHunter®
cAMP XS FL
cAMP XS FL
Any standard Fluorescence plate reader
Fluorescence
Excitation 530 ± 25 nm
Emission 610 ± 20 nm
Emission 610 ± 20 nm
HitHunter
cAMP XS+
cAMP XS+
Molecular Devices:
SpectraMax® L
Microplate Luminometer
SpectraMax® L
Microplate Luminometer
Chemiluminescence
Integration time: 1 second or 0.1 second
Mode: endpoint
PMT sensitivity: Auto Range
Calibration wavelength of 470 nm
Mode: endpoint
PMT sensitivity: Auto Range
Calibration wavelength of 470 nm
HitHunter
cAMP XS+
cAMP XS+
Index
CHAMELEON V
CHAMELEON V
Chemiluminescence
Integration time: 1 second
Mode: Direct Count
Mode: Direct Count
Application Notes
Instrument
Download
Copyright ©2012, DiscoveRx Corporation. TERMS AND CONDITIONS
0