HitHunter® cAMP

HitHunter® cAMP assays are routinely used in therapeutic campaigns to examine Gi and Gs pharmacology and function. These cAMP assays exhibit robust performance, reproducibility, flexibility and scalability that accelerates and simplifies bench-top assay development to high throughput screening. High tolerance to serum and plasma and broad compatibility to standard plate readers make it the most user-friendly, homogeneous, non-radioactive assay in the market.
View cAMP response on validated, native, non-force coupled Gs and Gi cell lines.
Product Features
Largest assay window, ideal for Gi targets
Proven miniaturization to 1536 and 3456
High sensitivity option enables cAMP detection in primary cells
inimize false positives with cleaner chemiluminescent detection
Positive gain-of-signal assay compatible with any standard plate reader
Applications
Monitoring Gi and Gs targets and identifying agonist, antagonist, allosteric,
partial agonists, inverse agonists
High throughput screening (HTS & uHTS) campaigns
Ligand Profiling
Use with primary cells, orphans, frozen and membrane
Identifying PDE inhibitors
How does it work?

For instrument compatibility, please click here.
Available Literature
Click here to view what we have available!

HitHunter® cAMP assays are competitive immunoassays. Free cAMP from cell lysates competes for antibody binding against
labeled cAMP (ED-cAMP conjugate). Unbound ED-cAMP is free to complement EA to form active enzyme by EFC, which subsequently
hydrolyzes substrate to produce signal. A positive signal generated is directly proportional to the amount of free cAMP bound
by the binding protein.